automobile
LASER BASED INSPECTION MACHINE
65 TON HYDROLIC PRESS
30 TON HYDROLIC PRESS
20 TON HYDROLIC PRESS
4 TON HYDROLIC PRESS
ADHESION TESTING MC
RECHROME LINE
PHOSPHATING LINE TRANSPORTER
HEIGHT TESTING MACHINE
glass labware
volumetric flask calibration machine
burette pipette calibration machine
cylinder joining machine
glass lathe machine
glass tube cutting machine
dry flask machine
taper testing machine
energy meter
single phase testing line
three phase testing line
hv megger testing machine
energy meter calibration line
hv megger three phase test machine
other
soap dispenser pump
colin dispenser pump assembly machine
dip tube mc
allout testing machine
silver vark
silver packet making mc
loreal cap detection
extension board test machine
cosmo ferrite core
x-y gantry
cnc loader
headlamp gluing
titan
screen printing
fan blade angle testing machine
about us
contact us
Functional, Error Testing & Calibration Conveyor Line for Single Phase Energy Meter
This is 15 station single phase meter testing conveyor.
This machine does following test:
– HV Megger Testing
– Functional Testing.
– Influence testing.
– Calibration.
– Error Testing
– Creep Test.
All electrical sources for testing are manufactured by us.
This is fully automatic testing conveyor where only loading/ un loading of meter is manual.
Testing data of every meter is stored in computer system.
Functional, Error Testing & Calibration Conveyor Line for Three Phase Energy Meter
This is 5 station Three phase meter testing conveyor.
3 meters are testing simultaneously.
This machine does following test:
– HV Testing
– Megger Testing
– Functional Testing.
– Calibration.
– Error Testing
All electrical sources for testing are manufactured by us.
This is fully automatic testing conveyor where only loading/ un loading of meter is manual.
Testing data of every meter is stored in computer system.
HV MEGGER TESTING MC. FOR ENERGY METER
This is 2 station Single phase meter testing conveyor.
3 meters are testing simultaneously.
This machine does following test:
– HV Testing
– Megger Testing
All electrical sources for testing are manufactured by us.
This is fully automatic testing conveyor where only loading/ un loading of meter is manual.
Testing data of every meter is stored in computer system.
Energy Meter Calibration Line
This is 5 station Three phase meter testing conveyor.
2 meters are testing simultaneously.
This machine does following test:
– HV Testing
– Megger Testing
–Functional Testing
–Calibration
–Error Testing
All electrical sources for testing are manufactured by us.
This is fully automatic testing conveyor where only loading/ un loading of meter is manual.
Testing data of every meter is stored in computer system.
HV Megger, Functional, Influence Testing & Calibration Conveyor Line for Three Phase Energy Meter
This is 6 station three phase meter testing conveyor.
This Conveyor is designed for testing 2 different meters.
This machine does following test:
– HV Megger Testing
– Influence testing
–Functional Testing
–Calibration 1
–Calibration 2
–Error Testing
All electrical sources for testing are manufactured by us.
This is fully automatic testing conveyor where only loading/ un loading of meter is manual.
Testing data of every meter is stored in computer system.